In the event that you ever need to manually retract the Talon, follow the procedure below.
- Press and hold the Up
button on the Indicator Panel until you hear 3 successive beeps. This will put the Talon in Manual Retraction Mode.
- Remove the Rubber Cap on the Manual Retraction Hex-Drive and use a 7/16" Socket Wrench, to turn the Hex-Drive in a clockwise direction.
- Continue to turn the Hex-Drive in a clockwise direction until the Talon is fully retracted. Visually confirm that the Spike is fully retracted.
- Once retracted, the Talon must be taken out of Manual Retraction Mode. Manual Retraction mode
will time-out after 30 minutes, or press and release the Upbutton on the Indicator Panel. Three
successive beeps will sound. This tone will confirm that the Talon has exited Manual Mode.